From: Is early full weight bearing safe following locking plate ORIF of distal fibula fractures?
| Plating System | minor complications | major complications | |
|---|---|---|---|
| DePuy Synthes® | Total | 4 (16%) | 2 (8%) |
| swelling and redness | 2 (8%) | ||
| deep vein thrombosis | 1 (4%) | ||
| superficial infection | 1 (4%) | ||
| deep wound infection | 2 (8%) | ||
| Newclip Technics® Active ankle system | Total | 2 (10%) | 1 (5%) |
| skin irritations by the implant | 2 (10%) | ||
| deep wound infection | 1 (5%) |